Carrier Furnace Repair London Ontario Carrier, Bryant and Payne
Carrier, Bryant and Payne furnaces share the same controls and the same two-digit status codes. We diagnose and repair all three for one flat service call, at any hour.
Quick answer: Hawana HVAC Solutions repairs Carrier, Bryant and Payne furnaces in London, Ontario for a $180 flat service call, 24 hours a day, with no after-hours surcharge. We read the two-digit status code, test the parts behind it and give you the price in writing before the repair. Call (519) 851-8518.
Flat, any hour, any day.
- After-hours surcharge$0
- Emergency arrival within 25 km1 to 2 hours
- PartsPriced in writing first
- Labour warranty1 year
- Tune-up$149
Carrier furnace models we repair
| Series | Models | Notes |
|---|---|---|
| Carrier Comfort | 59SC5, 59SC6, 58SB | Single-stage, the most common |
| Carrier Performance | 59TP6, 58TP | Two-stage |
| Carrier Infinity | 59MN7, 59TN6 | Modulating and variable-speed, communicating controls |
| Bryant | Legacy 912S and 915S, Preferred 926T, Evolution 987M | Same platform as Carrier |
| Payne | PG92, PG95, PG96 | Same platform, simpler controls |
| Older models | 58MCA, 58MXA, 58MVP, 58MTA | 90% furnaces from the 1990s and 2000s |
Not sure which one you have? The model number is on the rating plate inside the upper furnace door. Tell us that number when you call and we can bring the likely parts.
How to read the fault code on a Carrier furnace
Carrier furnaces flash a two-digit code on a light behind the lower door: a number of short flashes, then a number of long flashes. Code 33, for example, is three short and three long. The code is lost if the power is switched off.
| Code | What it means | Usual cause |
|---|---|---|
| 13 | Limit circuit lockout | Overheating for more than three minutes: filter, airflow or blower |
| 14 | Ignition lockout | No flame proven after four tries. Resets itself after three hours. |
| 31 or 32 | Pressure switch did not close or reopened | Blocked vent or drain, vent motor, pressure hose |
| 33 | Limit or rollout switch open | Dirty filter, closed vents, failing blower |
| 34 | Ignition proving failure | Dirty flame sensor, ignitor, gas supply |
| 22 | Flame sensed when the gas valve should be closed | Gas valve fault. Leave it off and call. |
| 24 | Low-voltage fuse open | Short in the thermostat wiring |
| 45 | Control board lockout | Control board |
Codes differ between models and control boards. The chart inside your furnace door is the final word for your model. For more brands, use the free furnace error code lookup.
Common Carrier furnace repairs and what they cost
| What you notice | What we usually find | Part price |
|---|---|---|
| Code 34, lights then shuts off | Dirty flame sensor | $150 to $250 |
| Code 14, no glow | Failed ignitor | $190 to $250 |
| Code 31 or 32, vent fan runs | Pressure switch, blocked condensate trap, or vent motor | $150 to $1,500 |
| Code 33 or 13, short heating cycles | Dirty filter first, then limit switch or blower motor | From the service call |
| Water around the furnace | Blocked condensate trap or cracked collector box hose | Cleared on the service call |
| No air or weak air | Blower motor or module | $500 to $1,500 |
| Code 45 or no light at all | Control board | $450 to $1,000 |
Part prices are for the part only, before HST, and vary by furnace model. The $180 flat service call is added once per visit and covers the diagnosis. You get the price in writing before any work starts.
Five things to check first
- Read the code before you cut the powerLook through the small window in the lower door and note the flashes or the code. On many furnaces, switching the power off erases it.
- Check the thermostatSet it to Heat, a few degrees above room temperature, with fresh batteries.
- Change the filterA blocked filter overheats the furnace and trips the limit switch.
- Check the vent pipes outsideClear snow, ice or leaves from the plastic intake and exhaust pipes.
- Reset onceTurn the furnace switch off for 30 seconds and back on. If it locks out again, call.
Smell gas or hear a carbon monoxide alarm? Leave the building first. Do not use light switches or phones inside. For a natural gas smell, call the Enbridge Gas emergency line at 1-866-763-5427 from outside. For propane, call your propane supplier. For a carbon monoxide alarm, call 911.
Carrier warranty and parts: what to know before you pay
Carrier, Bryant and Payne furnaces normally carry a 10-year parts warranty when the furnace was registered within 90 days of installation, and a shorter one if it was not. Heat exchanger coverage is longer and depends on the model. The warranty covers the part, not the labour.
Every furnace Hawana installs is registered with the manufacturer by us, so you get the full registered warranty without doing the paperwork yourself.
If your furnace is still inside its parts warranty, tell us when you call. Warranty parts for these brands are supplied through the brand’s own dealers, so in some cases the original installer is the cheaper route, and we will tell you honestly if it is. For furnaces outside warranty we use correct replacement parts and price them before the work.
Hawana HVAC Solutions is an independent heating contractor. Brand and model names belong to their owners and are used here only to describe the equipment we repair.
When to stop repairing a Carrier furnace
Carrier furnaces are solid, and most repairs are routine. Replacement is worth pricing on an older 90% model when the secondary heat exchanger is blocked or leaking, or when the repair is a large share of the price of a new furnace.
As a guide, repair a furnace under 10 years old, compare prices between 10 and 15 years, and plan to replace one over 15 years that needs a major part. A new Goodman high-efficiency furnace from Hawana starts at $3,500 installed, usually the day after you approve the quote. See furnace installation, or read why installation quality matters more than the brand.
Other brands and services
We also repair Goodman and Amana furnaces, Lennox furnaces, Trane and American Standard furnaces, York furnaces, Rheem and Ruud furnaces, KeepRite furnaces, Navien tankless water heaters, Rinnai tankless water heaters. See every make on the brands we service page. For general help, see furnace repair in London, 24-hour emergency service, the $149 furnace tune-up and air conditioner repair for the same brand.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Carrier furnace repair across London and nearby communities
- Byron
- Masonville
- Westmount
- Old North
- Old South
- White Oaks
- East London
- Riverbend
- Lambeth
- Komoka
- Dorchester
- Ilderton
- Delaware
- Arva
For repair, service and maintenance calls more than 25 km from London, a travel fee starting at $50 applies. The exact amount depends on your location and is confirmed before we dispatch, so there are no surprises. See all areas we serve.
About Hawana HVAC Solutions
Hawana HVAC Solutions is a heating and cooling company at 670 Millbank Dr, London, ON N6E 1S2, founded in 2021 by Abdullah Ghzail, who has more than 10 years in the trade. We are a TSSA-registered fuels contractor with $2 million in liability insurance and a BBB A+ rating. We repair Carrier and every other make of furnace across London and nearby communities, in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.

Carrier furnace questions, answered
How much does Carrier furnace repair cost in London Ontario?
Hawana HVAC Solutions charges a $180 flat service call at any hour, before HST. Common parts: flame sensor $150 to $250, ignitor $190 to $250, pressure switch $150 to $250, control board $450 to $1,000.
What does code 33 mean on a Carrier furnace?
A limit or rollout switch is open. The usual cause is overheating from a dirty filter, closed vents or a failing blower. If it stays open for three minutes the furnace locks out and shows code 13.
What does code 31 mean on a Carrier furnace?
The pressure switch did not close or it reopened. Check the vent pipes outside for snow or ice. Other causes are a blocked condensate drain, a cracked hose or a weak vent motor.
What does code 14 mean on a Carrier furnace?
Ignition lockout. The furnace tried to light four times and could not prove a flame. It resets itself after three hours, but the cause still needs to be fixed.
Are Bryant and Payne furnaces the same as Carrier?
They are made by the same company and share most parts and the same status codes, so they are diagnosed the same way.
How do I reset a Carrier furnace?
Turn the furnace switch off for 30 seconds and back on, once. Note the status code first, because cutting the power erases it.
Do you install Carrier furnaces?
Yes, on request. Carrier and Lennox furnaces start at $4,300 installed, before HST. A Goodman furnace starts at $3,500.
Carrier furnace down? Call now.
$180 flat service call. Any hour. Price in writing before the repair.