Navien Tankless Water Heater Repair London Ontario NPE, NPN and combi models
Navien is one of the two tankless brands we install, so we service them every week: error codes, no hot water, descaling and yearly maintenance.
Quick answer: Hawana HVAC Solutions repairs and services Navien tankless water heaters and combi boilers in London, Ontario for a $180 flat service call, 24 hours a day. Descaling is $199. We read the error code, test the parts behind it and give you the price in writing before the repair. Call (519) 851-8518.
Flat, any hour, any day.
- After-hours surcharge$0
- Tankless descaling$199
- PartsPriced in writing first
- New Navien or RinnaiFrom $3,600 installed
- Labour warranty1 year
Navien models we service
| Series | Models | Notes |
|---|---|---|
| NPE-A and NPE-A2 | NPE-180A, NPE-210A, NPE-240A and the A2 versions | Built-in recirculation pump and buffer tank |
| NPE-S and NPE-S2 | NPE-180S, NPE-210S, NPE-240S and the S2 versions | Standard models without the buffer tank |
| NPN | NPN-U and NPN-E series | Non-condensing models |
| Combi boilers | NCB-E, NCB-H | Heat the home and the hot water |
| Boilers | NHB, NFB, NFC | Heating boilers and fire-tube combis |
The model number is on the rating label on the side or bottom of the unit.
Common Navien error codes
A Navien shows an E code on the front panel when it shuts down. Note the code before you reset the unit.
| Code | What it means | Usual cause |
|---|---|---|
| E003 | Ignition failure | Gas supply, ignitor, flame rod or dirty burner |
| E004 | False flame detected | Flame rod or control fault |
| E012 | Flame loss | Gas pressure, venting, dirty flame rod or burner |
| E016 | Heat exchanger overheating | Scale build-up or low water flow. Needs descaling. |
| E030 | Exhaust overheating | Scale or a venting problem |
| E109 | Fan motor fault | Fan motor or its wiring |
| E110 | Exhaust or air pressure fault | Blocked vent, blocked condensate drain or air pressure sensor |
| E302 | Low water pressure (boilers and combis) | Loss of system water or pressure sensor |
| E515 | Control board fault | Control board |
Codes can differ between model series. Check the code list in your owner’s manual, and call if the code returns after one reset.
Common Navien problems we fix
| What you notice | What we usually find | What it costs |
|---|---|---|
| E003 or E012, no hot water | Dirty flame rod or burner, ignitor, or low gas pressure | Service call plus any part |
| E016, or water pulsing hot and cold | Scale on the heat exchanger | $199 descaling |
| E110 in winter | Ice or snow at the vent, or a frozen condensate line | Usually cleared on the service call |
| Lower flow at every hot tap | Clogged inlet filter or scale | Service call or descaling |
| Hot water takes a long time | Recirculation not set up, or pump fault | Service call plus any part |
| Water dripping from the unit | Leaking fitting, relief valve or heat exchanger | Priced after inspection |
The $180 flat service call covers the diagnosis. Any part is priced in writing before the work starts. Prices are before HST.
Five things to check first
- Note the error codeWrite down the code on the display or the remote controller before you reset anything.
- Check the power and gasThe unit must be plugged in, the breaker on and the gas valve open.
- Check the vent outsideClear snow, ice or nests from the intake and exhaust.
- Clean the inlet filterClose the cold water valve and rinse the small screen on the cold water inlet, if you are comfortable doing it.
- Reset onceSwitch the unit off and on at the controller. If the code returns, call.
Smell gas or hear a carbon monoxide alarm? Leave the building first. Do not use light switches or phones inside. For a natural gas smell, call the Enbridge Gas emergency line at 1-866-763-5427 from outside. For propane, call your propane supplier. For a carbon monoxide alarm, call 911.
Why a Navien needs descaling in the London area
London’s water is moderately hard, about 118 mg/L, and the water in Woodstock, Ingersoll and Tillsonburg is much harder. Minerals bake onto the heat exchanger of a tankless heater. The first signs are water that pulses hot and cold, lower flow, a louder burner and scale or overheating codes.
A yearly descale flushes the heat exchanger with a descaling solution, and we clean the inlet filter and check the burner at the same visit. Hawana charges $199 for tankless descaling. Homes on very hard water should also have a softener ahead of the heater.
Navien warranty: what to know
Navien NPE water heaters commonly carry a warranty of 15 years on the heat exchanger, 5 years on parts and 1 year on labour in a single-family home, when installed by a licensed contractor and registered. Coverage is shorter with recirculation in some setups and in commercial use, and the manufacturer can ask for proof of maintenance and water quality. Check the warranty certificate for your model.
Every water heater Hawana installs is registered with the manufacturer by us, so you get the full registered warranty without doing the paperwork yourself.
Hawana HVAC Solutions is an independent heating contractor. Brand and model names belong to their owners and are used here only to describe the equipment we repair.
Other brands and services
We also service Rinnai tankless water heaters and every make listed on the brands we service page. See water heater repair for tanks, tankless installation from $3,600 installed, and 24-hour emergency service.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Navien tankless repair across London and nearby communities
- Byron
- Masonville
- Westmount
- Old North
- Old South
- White Oaks
- East London
- Riverbend
- Lambeth
- Komoka
- Dorchester
- Ilderton
- Delaware
- Arva
For repair, service and maintenance calls more than 25 km from London, a travel fee starting at $50 applies. The exact amount depends on your location and is confirmed before we dispatch, so there are no surprises. See all areas we serve.
About Hawana HVAC Solutions
Hawana HVAC Solutions is a heating and cooling company at 670 Millbank Dr, London, ON N6E 1S2, founded in 2021 by Abdullah Ghzail, who has more than 10 years in the trade. We are a TSSA-registered fuels contractor with $2 million in liability insurance and a BBB A+ rating. We repair and install Navien and other tankless water heaters across London and nearby communities, in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.

Navien questions, answered
How much does Navien repair cost in London Ontario?
Hawana HVAC Solutions charges a $180 flat service call at any hour, before HST, which covers the diagnosis. Parts are priced in writing before the work. Descaling is $199.
What does error E003 mean on a Navien?
Ignition failure. The unit tried to light and could not. Common causes are a closed gas valve, low gas pressure, a failed ignitor or a dirty flame rod or burner.
What does error E016 mean on a Navien?
The heat exchanger is overheating, usually because scale has built up inside it or water flow is too low. The unit needs descaling.
What does error E110 mean on a Navien?
An exhaust or air pressure fault. Check the vent outside for snow, ice or a nest. A blocked condensate drain can cause it too.
How often should a Navien be descaled?
Once a year in the London area. In very hard water areas such as Woodstock and Ingersoll, use a water softener as well.
How long does a Navien tankless water heater last?
Often 15 to 20 years with yearly descaling and maintenance.
Do you install Navien water heaters?
Yes. A Navien or Rinnai tankless water heater starts at $3,600 installed, before HST.
Navien not making hot water? Call now.
$180 flat service call. Any hour. Descaling $199.