Many of London’s older homes, in Old North, Old South and Wortley Village, heat with a boiler and radiators. The system is simple and long-lived, and when a radiator goes cold the cause is usually air, pressure or a stuck valve.
Quick answer: If a radiator is cold at the top, it has trapped air and needs bleeding. If all radiators are cold, check the thermostat, the boiler switch and breaker, and the pressure gauge, which should read about 12 to 20 psi on a hot water system. Water under the boiler, a relief valve that drips or a boiler that will not fire need a technician. In London, Ontario, Hawana HVAC Solutions services hot water and steam boilers for a $250 flat service call, 24/7.
Flat, any hour, any day. Before HST.
- Normal pressure, hot water12 to 20 psi
- Hot water and steamBoth
- PartsQuoted in writing first
- New boilerQuoted on site
Key points
- Cold at the top, warm at the bottom: air. Bleed the radiator.
- Cold at the bottom, warm at the top: sludge. The system needs flushing.
- Pressure near zero means the system has lost water. Do not keep refilling; find the leak.
- Never cap or plug a dripping relief valve.
Safety first
Smell gas or hear a carbon monoxide alarm? Leave the building first. Do not use light switches or phones inside. For a natural gas smell, call the Enbridge Gas emergency line at 1-866-763-5427 from outside. For propane, call your propane supplier. For a carbon monoxide alarm, call 911.
Relief valve discharging, or pressure above 30 psi? Turn the boiler off and call. The relief valve is the boiler’s last safety device.
One radiator is cold
How to bleed a hot water radiator
- Turn the heat on and let the system warm up, then turn the thermostat down so the pump stops.
- Hold a cloth and a cup under the bleed valve at the top end of the radiator.
- Open the valve a quarter turn with a radiator key. Air will hiss out.
- Close it as soon as a steady stream of water appears.
- Check the boiler pressure afterwards; bleeding lowers it.
Also check that the radiator’s hand valve is open, and on systems with thermostatic radiator valves, that the pin under the head is not stuck.
Boiler will not fire? $250 flat, any hour.
All radiators are cold
- Thermostat: set above room temperature; replace batteries.
- Power: boiler switch and breaker on.
- Pressure gauge: about 12 to 20 psi cold on a hot water system. Near zero means lost water.
- Pilot or ignition: look for the pilot on older boilers; note any error code on newer ones.
- Circulator pump: boiler hot but pipes cold means the pump or a zone valve is not working.
- Gas supply: valve open, other gas appliances working.
Symptoms and likely causes
| Symptom | Likely cause |
|---|---|
| Radiator cold at the top | Trapped air |
| Radiator cold at the bottom | Sludge build-up |
| Some zones cold | Stuck zone valve or failed zone circulator |
| Boiler hot, radiators cold | Failed circulator pump, air lock |
| Pressure keeps dropping | Leak in the system or a failed expansion tank |
| Relief valve dripping | High pressure: failed expansion tank or fill valve |
| Banging or knocking pipes | Air, or on steam systems, water trapped in sloped pipes |
| Boiler will not fire | Ignition, flame sensor, gas valve, low-water cut-off or aquastat fault |
| Steam radiator hisses constantly or stays cold | Failed air vent on the radiator |
What boiler repair costs in London
Boiler service is a $250 flat service call at any hour, before HST, with no after-hours surcharge. Parts are quoted in writing before work. We service radiators, baseboards and in-floor heating on hot water and steam systems. Boiler replacements are quoted on site. See boiler repair.
Looking after a boiler system
- have the boiler serviced every fall: burner, ignition, safety controls, combustion check
- bleed radiators at the start of each heating season
- glance at the pressure gauge monthly
- keep the area around the boiler clear
- never let the house freeze: a frozen radiator loop can split pipes; see preventing frozen pipes
- keep carbon monoxide alarms on every storey
Want air conditioning in a radiator-heated home? Ductless mini-splits add cooling without ductwork.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Radiators and boilers: common questions
Why is my radiator cold at the top?
Air is trapped in it. Bleed the radiator with a radiator key until water appears, then check the boiler pressure.
What should my boiler pressure be?
About 12 to 20 psi when cold on a typical residential hot water system. Near zero means the system has lost water; above 30 psi the relief valve will discharge.
Why are all my radiators cold?
Check the thermostat, the boiler power switch and breaker, and the pressure gauge. If the boiler is hot but the pipes are cold, the circulator pump or a zone valve has failed.
How much does boiler repair cost in London Ontario?
Hawana HVAC Solutions charges a $250 flat service call for boilers at any hour, before HST. Parts are quoted in writing before work starts.
Why are my heating pipes banging?
In hot water systems, usually trapped air. In steam systems, water pooling in pipes or radiators that have lost their slope. Both are fixable.
How often should a boiler be serviced?
Once a year, before the heating season.
About Hawana HVAC Solutions
This guide was written by Abdullah Ghzail, owner of Hawana HVAC Solutions, 670 Millbank Dr, London, ON N6E 1S2. Abdullah has more than 10 years in the heating and cooling trade and founded the company in 2021. Hawana is a TSSA-registered fuels contractor (registration 000396738) with $2 million in liability insurance and a BBB A+ rating, serving London and nearby communities in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.