Furnace Leaking Water? 7 causes and what to do
By Abdullah Ghzail, owner of Hawana HVAC SolutionsUpdated 3 min read
A puddle under the furnace looks alarming, and it should be dealt with quickly, but the cause is usually a blocked drain, not a ruined furnace. What it is depends a lot on the season.
Quick answer: A furnace leaking water is most often caused by a clogged condensate drain or trap on a high-efficiency furnace. In summer the water usually comes from the air conditioner’s coil and drain pan above the furnace. Other causes are a leaking humidifier, a cracked condensate line or pump failure. Turn the system off, mop up the water, check the drain hose and the humidifier, and call a technician if the leak returns. It is rarely dangerous, but water can damage the control board and the floor.
Flat, any hour. Before HST.
- AC drain pan and line cleaning$150
- Most common causeBlocked condensate drain
- In summerUsually the AC coil
- Dangerous?Rarely, but act fast
Key points
- High-efficiency furnaces make water on purpose; it should go down a drain, not onto the floor.
- Winter leak: think condensate drain, trap or humidifier. Summer leak: think air conditioner.
- Switch the system off if water is near the control board or wiring.
- A furnace with a metal vent pipe should never leak water; if it does, call.
What to do first
- Turn the furnace or air conditioner off at the thermostat.
- If water is near wiring or the control board, turn off the furnace switch too.
- Mop up the water so you can see where new water comes from.
- Check the filter. A clogged filter can freeze the AC coil, which then melts and overflows.
- Look at the clear or white plastic drain tubing for kinks, disconnections or slime.
- Check the humidifier on the ductwork for drips.
- If the cause is not obvious or it leaks again, call for service.
The 7 most common causes
| Cause | Season | What you see | Fix |
|---|---|---|---|
| Clogged condensate drain line or trap | Winter | Water at the base of a high-efficiency furnace | Clean and flush the trap and line |
| Failed condensate pump | Any | Full pump reservoir, water around the pump | Replace the pump |
| Leaking humidifier | Winter | Drips from the humidifier or its drain hose | New pad, clear the drain, fix the supply valve |
| Cracked or loose drain hose or fitting | Any | Drip from a joint in the plastic tubing | Reseal or replace |
| Blocked AC drain pan or line | Summer | Water from the coil cabinet above the furnace | Drain pan and line cleaning, $150 |
| Frozen AC coil thawing | Summer | Lots of water after the AC ran with poor airflow | New filter; find the airflow or refrigerant cause |
| Internal furnace leak: collector box, inducer housing or secondary heat exchanger | Winter | Water inside the furnace cabinet, rust streaks | Technician repair; on old furnaces, compare with replacement |
Leak keeps coming back? $180 flat, any hour.
Why a furnace makes water at all
A high-efficiency (condensing) furnace squeezes so much heat out of the exhaust that water vapour in it condenses, the same way a cold glass sweats. That water, several litres a day in cold weather, drains through a trap and a hose to a floor drain or a small pump. The furnaces we see leaking are usually working properly; their drain is not.
A mid-efficiency furnace with a metal vent does not condense. Water at one of those points to the humidifier, the air conditioner or a venting problem.
Is a leaking furnace dangerous?
The water itself is not hazardous, but three things make it urgent:
- water reaching the control board or wiring can short out the furnace, a $450 to $1,000 repair
- a blocked condensate drain will trip the pressure switch and shut the furnace down, usually on a cold night
- long-term leaks rust the cabinet and can lead to mould under flooring
If you also smell exhaust, or a carbon monoxide alarm sounds, leave the house and call 911.
What it costs to fix
The service call is $180 flat at any hour. Clearing a condensate drain is often done within that visit; parts such as a condensate pump or humidifier valve are quoted in writing first. Air conditioner drain pan and drain line cleaning is $150, and it is included with a maintenance plan. See furnace repair.
How to prevent it
- have the condensate trap and drain flushed during the yearly furnace tune-up
- replace the humidifier pad every fall
- change the filter on schedule so the AC coil never freezes
- pour a cup of water into the floor drain occasionally so its trap does not dry out
- keep the drain hose routed downhill with no kinks
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Furnace leaking water: common questions
Why is my furnace leaking water?
Most often because the condensate drain or trap on a high-efficiency furnace is clogged. Other causes are a leaking humidifier, a failed condensate pump, or in summer the air conditioner’s drain pan above the furnace.
Is a furnace leaking water dangerous?
The water is not hazardous, but it can short out the control board, shut the furnace down and cause rust and mould. Turn the system off and have it fixed promptly.
Why is my furnace leaking water when the AC is on?
The water is coming from the air conditioner’s evaporator coil, which sits on top of the furnace. Its drain pan or drain line is blocked, or the coil froze and is thawing.
Can I still run my furnace if it is leaking water?
Only if the water is clearly away from the electrical parts and you are waiting for service in cold weather. Otherwise turn it off to avoid damaging the control board.
How much does it cost to fix a leaking furnace?
Hawana HVAC Solutions charges a $180 flat service call. Clearing a drain is often completed in that visit; parts are quoted in writing first. AC drain pan and line cleaning is $150.
Why is water leaking from the bottom of my furnace in winter?
A high-efficiency furnace produces condensate in heating mode. A blocked trap, drain hose or pump makes it back up and spill from the bottom of the cabinet.
About Hawana HVAC Solutions
This guide was written by Abdullah Ghzail, owner of Hawana HVAC Solutions, 670 Millbank Dr, London, ON N6E 1S2. Abdullah has more than 10 years in the heating and cooling trade and founded the company in 2021. Hawana is a TSSA-registered fuels contractor (registration 000396738) with $2 million in liability insurance and a BBB A+ rating, serving London and nearby communities in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.