Mitsubishi, Daikin and Fujitsu Heat Pump Repair London Ontario Ductless and mini-split, all brands
Blinking lights, an error code, ice on the outdoor unit or water dripping inside? We repair ductless heat pumps and mini-splits of every major brand for one flat service call.
Quick answer: Hawana HVAC Solutions repairs Mitsubishi, Daikin, Fujitsu, LG, Gree and other ductless heat pumps in London, Ontario for a $180 flat service call, 24 hours a day. We read the error code, find refrigerant leaks, and replace fan motors, boards and sensors, with the price in writing before the repair. Call (519) 851-8518.
Flat, any hour, any day.
- After-hours surcharge$0
- CapacitorFrom $150
- Fan motorFrom $500
- Control boardFrom $500
- R-410A refrigerant$80 per lb
Ductless and heat pump brands we repair
| Brand | Common models | Notes |
|---|---|---|
| Mitsubishi Electric | M-Series MSZ and MUZ, Hyper-Heat (H2i), MXZ multi-zone | Error codes shown on the remote, such as P and U codes |
| Daikin | Aurora, 17 and 19 Series, FTX and RX model numbers | Codes such as U0, U4, A5 and E7 shown on the remote |
| Fujitsu | Halcyon, RLS and RLF series | Faults shown by the Operation and Timer lights blinking |
| LG, Gree, Tosot, Midea, Senville | Wall, floor and multi-zone systems | Codes such as E1, E6, H3 and F-series on the display |
| Kepler, Comfort Star, Kinghome | The brands we install most | Cold-climate models rated to -30°C |
The model number is on the label on the side of the outdoor unit and under the front panel of the indoor unit.
Common Daikin and Mitsubishi error codes
To read a code, follow the check procedure in the owner’s manual for your remote. Note the code before you switch the power off.
| Brand and code | What it means | Usual cause |
|---|---|---|
| Daikin U0 | Refrigerant shortage | A leak. Must be found and repaired. |
| Daikin U2 | Voltage too low or too high | Power supply problem |
| Daikin U4 | Signal error between indoor and outdoor units | Wiring, outdoor power or control board |
| Daikin A5 | Freeze-up or high-pressure protection | Dirty filters or coil, low airflow |
| Daikin A6 or E7 | Indoor or outdoor fan motor fault | Fan motor or its wiring |
| Daikin E5 or E6 | Compressor overload or lock | Low refrigerant, dirty outdoor coil, compressor fault |
| Mitsubishi E6 or E7 | Communication error between indoor and outdoor units | Wiring or control board |
| Mitsubishi P5 | Drain overflow | Blocked condensate drain or failed drain pump |
| Mitsubishi P6 | Freeze or overheat protection | Dirty filters, low airflow or low refrigerant |
| Mitsubishi U2 | High discharge temperature | Low refrigerant or a blocked outdoor coil |
Codes differ between model series. The service manual for your model is the final word, and other brands use different codes.
Common ductless problems and part prices
| What you notice | What we usually find | Part price |
|---|---|---|
| Runs but does not heat or cool | Low refrigerant from a leak | R-410A $80 per lb; leak repair depends on location |
| Water dripping from the indoor unit | Blocked condensate drain or dirty coil | Cleared on the service call; coil cleaning $350 |
| Outdoor unit covered in ice | Defrost board or sensor fault, or blocked airflow | Defrost board from $700 |
| Outdoor fan not turning | Fan motor or capacitor | Fan motor from $500; capacitor from $150 |
| Blinking lights, no start | Control board or communication wiring | Control board from $500 |
| Weak airflow or bad smell | Dirty filters, blower wheel and coil | Cleaning |
Part prices are for the part only, before HST. The $180 flat service call is added once per visit. You get the price in writing before any work starts.
Five things to check first
- Note the code or the blinking lightsWrite down the code on the remote or how the lights on the indoor unit blink, before you reset anything.
- Check the mode and the remoteSet the mode to Heat or Cool, not Fan or Dry, and replace the remote batteries.
- Clean the filtersOpen the front panel, slide out the mesh filters, wash and dry them. Blocked filters cause icing and weak airflow.
- Clear the outdoor unitRemove snow, ice and leaves from around and under the outdoor unit.
- Reset onceTurn the breaker off for five minutes and back on. If the code returns, call.
Refrigerant and leaks
A ductless system does not use up refrigerant. If it is low, there is a leak, most often at a flare connection made during installation. We find and repair the leak, pressure-test, pull a vacuum and then recharge by weight. Most systems use R-410A, and newer ones use R-32. Topping up without repairing the leak only delays the same failure.
Hawana HVAC Solutions is an independent heating contractor. Brand and model names belong to their owners and are used here only to describe the equipment we repair.
When to replace a ductless system
Repair a system under 10 years old when the fault is a fan motor, board, sensor or a repairable leak. Replacement is worth pricing when the compressor has failed outside warranty, or the system is over 12 to 15 years old. A new single-zone ductless heat pump starts at $3,900 installed and a multi-zone system at $5,900, before HST. See ductless systems.
Other brands and services
Central heat pump or air conditioner? See heat pump repair and AC repair. Every make we service is on the brands we service page. For urgent problems, see 24-hour emergency service.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Ductless heat pump repair across London and nearby communities
- Byron
- Masonville
- Westmount
- Old North
- Old South
- White Oaks
- East London
- Riverbend
- Lambeth
- Komoka
- Dorchester
- Ilderton
- Delaware
- Arva
For repair, service and maintenance calls more than 25 km from London, a travel fee starting at $50 applies. The exact amount depends on your location and is confirmed before we dispatch, so there are no surprises. See all areas we serve.
About Hawana HVAC Solutions
Hawana HVAC Solutions is a heating and cooling company at 670 Millbank Dr, London, ON N6E 1S2, founded in 2021 by Abdullah Ghzail, who has more than 10 years in the trade. We are a TSSA-registered fuels contractor with $2 million in liability insurance and a BBB A+ rating. We repair and install ductless heat pumps of every major brand across London and nearby communities, in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.

Ductless questions, answered
How much does ductless heat pump repair cost in London Ontario?
Hawana HVAC Solutions charges a $180 flat service call at any hour, before HST. Part prices: capacitor from $150, fan motor from $500, control board from $500, defrost board from $700, and R-410A refrigerant $80 per pound.
Do you repair Mitsubishi, Daikin and Fujitsu heat pumps?
Yes. We repair those and LG, Gree, Tosot, Kepler, Comfort Star, Kinghome, Midea and Senville ductless systems.
What does error U4 mean on a Daikin?
A signal transmission error between the indoor and outdoor units. Causes include a wiring fault, a power problem at the outdoor unit or a failed control board.
What does error U0 mean on a Daikin?
Refrigerant shortage. The system has a leak that must be found and repaired before it is recharged.
Why is my ductless unit blinking?
A blinking light is a fault signal. The pattern, or the code shown on the remote, identifies the fault. Note it before you reset the unit.
Why is my heat pump not heating in very cold weather?
It may be in defrost, which is normal for a few minutes, or the outdoor unit may be iced over. Standard models also lose capacity below about -15°C. Cold-climate models are rated to -30°C.
How often should a ductless system be serviced?
Wash the filters every month in season and book a professional cleaning and check once a year.
Ductless system down? Call now.
$180 flat service call. Any hour. Every major brand.