By Abdullah Ghzail, owner of Hawana HVAC SolutionsUpdated 3 min read
The fan is running, air is coming from the vents, and it is cold. That narrows the problem down nicely: the blower works, so the fault is in making the heat or in the settings telling the fan when to run.
Quick answer: A furnace that runs but does not blow hot air usually has the thermostat fan set to On instead of Auto, a clogged filter that has made the furnace overheat and shut off its burners, a dirty flame sensor, or a failed ignitor. Set the fan to Auto, replace the filter, and reset the furnace once. If the air is still cold, the flame sensor, ignitor or gas supply needs a technician.
Flat, any hour. Before HST.
- Flame sensor$150 to $250
- Ignitor$190 to $250
- Easy fix #1Fan to Auto
- Easy fix #2New filter
Key points
- Fan set to On blows unheated air between heating cycles. Auto is the normal setting.
- A clogged filter is the most common real fault: the burners shut off on the high-limit switch.
- Burners that light then go out within seconds point to a dirty flame sensor.
- Reset the furnace once only.
Four easy fixes to try first
- Set the thermostat fan to Auto. On runs the blower all the time, so you feel cool air whenever the burners are off.
- Replace the furnace filter. Then wait ten minutes for the furnace to cool and try again.
- Check the thermostat. Heat mode, setpoint above room temperature, fresh batteries.
- Reset the furnace once. Turn the furnace switch off for 60 seconds and back on.
Cool air for the first minute is normal. The blower starts shortly after the burners; the first air out of the ducts has been sitting in a cold basement.
The 9 most common causes
| Cause | Clue | Fix |
|---|---|---|
| Fan set to On | Cool air between cycles, warm air during them | Set to Auto |
| Clogged filter | Warm air, then cold, then the furnace stops | Replace the filter |
| Dirty flame sensor | Burners light, then shut off after a few seconds | Clean or replace: $150 to $250 |
| Failed ignitor | Clicking or glow missing, burners never light | Replace: $190 to $250 |
| Gas supply off or low | No flame; other gas appliances may also be out | Check the valve; call the gas utility or a technician |
| Blocked vent or condensate drain | Furnace tries to start, then locks out with a code | Clear the vent pipes; clean the drain |
| Pressure switch fault | Inducer runs, burners never light | Repair: $150 to $250 |
| Failed gas valve or control board | Ignitor glows, no gas flows | Repair: $450 to $1,200 |
| Leaky or disconnected ducts | Furnace is hot, some vents are cold | Duct repair |
Installed part prices are before HST and are in addition to the $180 service call.
Easy fixes did not work? $180 flat, any hour.
Read the pattern
- Always cold: burners are not lighting. Ignitor, gas supply, pressure switch or control.
- Hot, then cold: burners are shutting off early. Filter, flame sensor or high-limit switch.
- Cold only between cycles: fan setting.
- Some rooms cold: ducts, dampers or closed vents, not the furnace.
If you have a heat pump or hybrid system
Heat pump supply air is cooler than furnace air, about 30 to 40 C, and can feel cool on your hand while still heating the house. During a defrost cycle it may blow cool air for a few minutes. That is normal. If the house is losing temperature, read heat pump not heating in winter.
When to call
- the burners light and go out repeatedly
- the furnace shows an error code or locks out
- you hear booming, grinding or squealing
- you smell gas: leave the house and call from outside
- the house is getting cold and the checks have not helped
Hawana answers 24 hours a day at (519) 851-8518: furnace repair, $180 flat, with the part price in writing first. Full price list: furnace repair cost.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Furnace blowing cold air: common questions
Why is my furnace blowing cold air?
The most common reasons are the thermostat fan set to On, a clogged filter that makes the burners shut off, a dirty flame sensor, or a failed ignitor.
Why is my furnace running but not heating?
The blower is working but the burners are not staying lit. Replace the filter and reset the furnace once. If the burners light and go out within seconds, the flame sensor needs cleaning or replacing.
Is there an easy fix for a furnace not blowing hot air?
Often, yes: set the thermostat fan to Auto, replace the filter, check the thermostat batteries and reset the furnace once.
Why does my furnace blow cold air and then hot?
A short burst of cool air at the start of a cycle is normal. If it blows hot then cold, the burners are shutting off early, usually from a dirty filter or flame sensor.
How much does it cost to fix a furnace blowing cold air?
Hawana HVAC Solutions charges a $180 flat service call. A flame sensor is $150 to $250 and an ignitor $190 to $250 installed, before HST.
Should I turn off my furnace if it is blowing cold air?
If it keeps trying to light and failing, yes, turn it off and call. Repeated failed ignition is hard on the furnace.
About Hawana HVAC Solutions
This guide was written by Abdullah Ghzail, owner of Hawana HVAC Solutions, 670 Millbank Dr, London, ON N6E 1S2. Abdullah has more than 10 years in the heating and cooling trade and founded the company in 2021. Hawana is a TSSA-registered fuels contractor (registration 000396738) with $2 million in liability insurance and a BBB A+ rating, serving London and nearby communities in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.

Still cold? We answer 24/7.
$180 flat service call, any hour. Part price in writing first.