Gas Fireplace Won’t Light? 7 checks and common fixes
By Abdullah Ghzail, owner of Hawana HVAC SolutionsUpdated 3 min read
Gas fireplaces sit unused for months and then refuse to light on the first cold evening. Most of the time the cause is small: dead batteries, a pilot that needs relighting, or a tired thermocouple.
Quick answer: If a gas fireplace will not light, check that the gas valve is open, relight the pilot following the instructions on the unit, replace the batteries in the remote and receiver, and check the power for electronic ignition models. A pilot that will not stay lit usually means a worn thermocouple or thermopile, or a dirty pilot assembly. In London, Ontario, Hawana HVAC Solutions repairs gas fireplaces of all major brands for a $180 flat service call.
Flat, no after-hours surcharge. Before HST.
- PartsQuoted in writing first
- BrandsAll major
- Natural gas and propaneBoth
- Best time to serviceEarly fall
Key points
- Batteries in the remote and the receiver box cause a large share of ‘dead’ fireplaces.
- Pilot lights but goes out when you release the knob: thermocouple.
- Pilot stays lit but the main burner will not come on: thermopile, switch or gas valve.
- Soot on the glass or logs means poor combustion: stop using it and have it serviced.
Safety first
Smell gas or hear a carbon monoxide alarm? Leave the building first. Do not use light switches or phones inside. For a natural gas smell, call the Enbridge Gas emergency line at 1-866-763-5427 from outside. For propane, call your propane supplier. For a carbon monoxide alarm, call 911.
7 checks before you call
- Check the gas valve. The shut-off near the fireplace should be in line with the pipe.
- Check the pilot. Look for a small flame behind the logs. If it is out, follow the lighting instructions on the plate inside the lower panel.
- Check the wall switch, remote and batteries. Replace the batteries in the remote and in the receiver box under the fireplace.
- Check the power. Fireplaces with electronic ignition or a fan need power. Check the breaker and the plug.
- Hold the pilot knob longer. After lighting a standing pilot, hold the knob in for 30 to 60 seconds so the thermocouple heats up.
- Clean the glass and check for soot. Heavy soot means poor combustion and needs a technician.
- Stop if you smell gas. Turn the gas off, ventilate, leave and call.
Fireplace not lighting? Get it fixed.
Thermocouple, thermopile and ignition, explained
A thermocouple sits in the pilot flame and generates a tiny voltage that holds the gas valve open. If the pilot goes out, it cools and shuts the gas off. When it wears out, the pilot will not stay lit.
A thermopile is a larger version that generates enough power to open the main burner valve when you flip the switch or press the remote. A weak thermopile gives a pilot that stays lit but a burner that will not start, or one that cuts out.
Electronic ignition fireplaces have no standing pilot. A module sparks the pilot on demand and a flame sensor proves it. These need power or backup batteries.
Symptoms and likely causes
| Symptom | Likely cause |
|---|---|
| Pilot will not light at all | Gas off, air in the line after summer, blocked pilot orifice, failed ignitor |
| Pilot lights, goes out when the knob is released | Worn thermocouple, dirty pilot, weak flame |
| Pilot on, main burner will not light | Weak thermopile, bad wall switch or remote, failed gas valve |
| Clicking but no flame | No gas, dirty or misaligned ignitor, failed module |
| Burner lights then shuts off | Weak thermopile, flame sensor, blocked vent |
| Soot on glass or logs | Logs out of position, blocked air shutter, poor combustion |
| Fan will not run | Failed fan, fan thermostat or speed control |
| Remote does nothing | Batteries, receiver switch position, lost pairing |
What gas fireplace repair costs
The service call is $180 flat with no after-hours surcharge. Any part is quoted in writing before work. We repair pilots, thermocouples and thermopiles, gas valves, ignition modules, remotes and fans on all major brands, natural gas and propane. See gas fireplace repair.
Yearly gas fireplace maintenance
- have it serviced before the heating season: pilot and burner cleaning, gasket check, vent check, combustion check
- clean the glass with fireplace glass cleaner, never when hot
- replace remote and receiver batteries every fall
- keep the vent termination outside clear of snow, nests and plants
- have carbon monoxide alarms on every storey; see carbon monoxide and your furnace
Adding a fireplace or moving one needs a gas line; see the gas line guide.
What our customers say
These are live reviews from our Google Business Profile, shown as customers wrote them, from homeowners in London and the towns we serve. 247+ customers have left five stars.
Gas fireplaces: common questions
Why won’t my gas fireplace light?
The most common causes are a closed gas valve, a pilot that has gone out, dead batteries in the remote or receiver, no power to an electronic ignition unit, or a worn thermocouple or thermopile.
Why won’t my gas fireplace pilot stay lit?
Usually a worn thermocouple or a dirty pilot assembly. Hold the pilot knob in for 30 to 60 seconds after lighting; if it still goes out, the thermocouple likely needs replacing.
How much does gas fireplace repair cost in London Ontario?
Hawana HVAC Solutions charges a $180 flat service call, before HST, with no after-hours surcharge. Parts are quoted in writing before work starts.
Should I leave my gas fireplace pilot on all year?
You can turn it off in summer to save a small amount of gas. Leaving it on keeps moisture and spiders out of the pilot tube. Either is fine; follow the manufacturer’s guidance.
How often should a gas fireplace be serviced?
Once a year, ideally in early fall before you start using it.
Is it safe to use a gas fireplace with soot on the glass?
No. Soot means incomplete combustion, which can produce carbon monoxide. Stop using the fireplace and have it serviced.
About Hawana HVAC Solutions
This guide was written by Abdullah Ghzail, owner of Hawana HVAC Solutions, 670 Millbank Dr, London, ON N6E 1S2. Abdullah has more than 10 years in the heating and cooling trade and founded the company in 2021. Hawana is a TSSA-registered fuels contractor (registration 000396738) with $2 million in liability insurance and a BBB A+ rating, serving London and nearby communities in English and Arabic. Phone (519) 851-8518 or (647) 550-4220. Read more about our team.

Fireplace not lighting? Get it fixed.
$180 flat service call. Natural gas and propane, all major brands.